1600 kVA 35 kV Dry-Type Grounding Transformer with Resin-Cast HV Windings

The 1600 kVA 35 kV dry-type grounding transformer features resin-cast high-voltage windings, aluminum conductors, a Zn connection, natural air cooling, and F-class insulation. Designed for medium-voltage grounding applications, it offers an oil-free solution for power systems requiring a dedicated grounding transformer.


Follow us on social media for the latest product updates, transformer knowledge, factory news, and exhibition highlights.

https://www.facebook.com/profile.php?id=100078707262551

Share:

Basic Info.

The 1600 kVA 35 kV Dry-Type Grounding Transformer is designed for grounding applications in medium-voltage power systems. It can provide a neutral point for systems where one is not directly available, depending on the system configuration and grounding requirements.

The transformer features resin-cast high-voltage windings and an aluminum winding conductor design. Its zigzag (Zn) connection is intended for grounding applications, helping establish a suitable neutral point for the associated grounding and protection scheme.

With AN natural air cooling and F-class insulation, this dry-type grounding transformer is designed for operation under the specified electrical and environmental conditions. Its oil-free construction may be suitable for installations where oil-filled equipment is not preferred.


Applications

The 1600 kVA 35 kV Dry-Type Grounding Transformer can be used in medium-voltage power systems that require a dedicated grounding transformer, subject to compatibility with the system design.

Potential applications include:

Medium-voltage distribution substations

Industrial power distribution systems

Renewable energy projects with compatible grounding arrangements

Power systems requiring a neutral point for grounding and earth-fault protection

The transformer should be selected according to the system voltage, grounding method, required earth-fault current, fault duration, and protection coordination requirements.


Performance parameters for reference

ParameterSpecification
Rated power1600 kVA
Rated high voltage35 kV
Maximum working high voltage40.5 kV
PhaseThree-phase
Winding materialAluminum
High-voltage windingResin-cast
Vector groupZn
Frequency50 Hz
Cooling methodAN (natural air cooling)
Insulation classF



Contact us
Key Features

Resin-Cast High-Voltage Windings

The high-voltage windings use resin-cast insulation, providing solid insulation and mechanical support. This construction is suitable for applications requiring dry-type transformer equipment.

Zigzag (Zn) Connection

The Zn connection is commonly used in grounding transformers to establish a neutral point in compatible power systems. The final configuration should be confirmed according to the system grounding method and protection requirements.

F-Class Insulation

The transformer uses an F-class insulation system. Its insulation and thermal performance depend on the complete design and specified operating conditions.

AN Natural Air Cooling

The AN cooling method uses natural air circulation without forced-air cooling. Adequate ventilation and installation clearances should be provided in accordance with the manufacturer's requirements.

Specified Partial Discharge Level

The specified partial discharge level is ≤10 pC. Compliance should be verified under the applicable test conditions and agreed acceptance criteria.


Second, the core advantages and characteristics of the product

Manufacturing and Quality Control

TAILI can manufacture grounding transformers according to agreed project specifications. Key parameters, including the electrical configuration, insulation level, cooling method, and installation conditions, should be confirmed before production.

Routine tests and other agreed inspections can be arranged according to the applicable standards and contractual requirements.


Customized Grounding Transformer Solutions

TAILI provides customized transformer solutions for medium-voltage power systems. The technical configuration can be reviewed according to project requirements, including grounding arrangements, insulation, cooling, and installation conditions.

Contact our engineering team with your system voltage, grounding method, required earth-fault current, and installation details to confirm the appropriate technical configuration.