Product Knowledge

Why Do Some Dry-Type Transformers Have Through-Holes in the Core?

November 09, 2026

Share:

What Are Through-Holes in a Transformer Core?

Some dry-type transformers, including certain designs used in the Russian and Eastern European markets, feature holes incorporated into their laminated iron cores.

These holes may be designed to accommodate through-bolts or other fastening components, depending on the core construction and clamping arrangement.

Unlike mounting holes in external support frames, these holes are incorporated into the core lamination design and require careful consideration during manufacturing.

Why Are Through-Holes Used in Dry-Type Transformer Cores?

1. Improve Core Clamping and Mechanical Stability

A transformer core consists of multiple laminated silicon steel sheets. Proper clamping is essential to maintain the mechanical integrity of the core assembly.

In certain designs, through-bolts are used to connect and secure different parts of the core structure. This arrangement helps limit relative movement between components during transportation and operation.

2. Improve Structural Stability During Operation

During operation, electromagnetic forces associated with alternating magnetic flux can cause core vibration.

A properly designed fastening structure helps maintain the stability of the core assembly and may reduce vibration caused by loose or insufficiently secured components.

However, transformer noise also depends on factors such as core material, magnetic flux density, lamination quality, and assembly accuracy.

3. Enhance Transportation Stability

Power transformers may experience mechanical shocks and vibration during transportation, particularly when shipped over long distances.

For large dry-type transformers, appropriate mechanical fastening helps maintain the integrity of the core assembly and reduces the risk of structural movement during handling and transportation.

Do Core Through-Holes Affect Transformer Performance?

Although through-holes can provide mechanical benefits, their design must also consider electromagnetic performance.

Magnetic Flux Distribution: Through-holes may reduce the effective cross-sectional area of the core and affect the local magnetic flux distribution.

No-Load Losses: Improper punching or cutting may damage silicon steel laminations, potentially increasing core losses.

Local Temperature Rise: If the effective core cross-section is reduced excessively, local magnetic flux density may increase, potentially resulting in additional losses and temperature rise.

Therefore, hole dimensions, positions, quantities, and manufacturing quality should be considered during electromagnetic and structural design.

Are Through-Holes a Standard Requirement for Russian Dry-Type Transformers?

Not necessarily. Through-hole core designs can be found in some transformer products manufactured for the Russian and Eastern European markets, but they are not a universal requirement for all Russian dry-type transformers.

The choice of core construction depends on the manufacturer's design approach, mechanical requirements, transformer capacity, manufacturing processes, and customer specifications.

Different manufacturers may use conventional external clamping structures, through-bolt arrangements, or combined fastening methods.

What Should Manufacturers Consider When Designing Core Through-Holes?

For transformer manufacturers, incorporating through-holes into a core requires coordination between electromagnetic design and mechanical construction.

Important considerations include:

Hole Position: Avoid unnecessary interference with the main magnetic flux path.

Hole Dimensions: Ensure sufficient space for fastening components without excessively reducing the effective core cross-section.

Punching Quality: Minimize burrs and mechanical damage to silicon steel laminations.

Insulation Protection: Prevent conductive fastening components from creating unintended electrical connections between laminations.

Clamping Force: Apply appropriate fastening pressure without damaging the core or compromising its magnetic properties.

A well-designed structure should balance mechanical strength, magnetic performance, and manufacturing feasibility.

Conclusion

Through-holes in dry-type transformer cores are generally associated with mechanical fastening, core clamping, and structural stability. Depending on the design, they can help secure the core assembly and improve its mechanical integrity.

However, these holes must be carefully designed to avoid unnecessarily affecting the effective magnetic cross-section and overall transformer performance.

For transformer manufacturers and buyers, understanding the purpose of these structural features helps ensure that the final transformer meets both electrical and mechanical requirements.