Amorphous Alloy Dry Type Transformers

Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer

Amorphous Alloy Dry Type Transformer

TAILI Silent SCBH15 Amorphous Alloy Dry Type Transformer is a perfect combination of an amorphous alloy core and a resin-insulated dry-type transformer. It is a new type of energy-saving transformer. It has the energy-saving performance of an amorphous alloy core, while keeping all the features of a resin-insulated dry-type transformer.


Our amorphous core transformer (amorphous metal dry-type transformer) is designed to significantly reduce energy loss in power distribution systems. By using advanced amorphous alloy core materials, the transformer achieves much lower no-load loss compared with conventional silicon steel core transformers, making it an ideal choice for projects focusing on energy efficiency and long-term operating cost reduction.


Unlike traditional transformers, the amorphous metal structure minimizes magnetic hysteresis loss, helping improve overall system efficiency, especially in applications where the transformer remains energized for extended periods.


Share:

Silent Dry Type Amorphous Core Transformer

TAILI SCBH15 amorphous alloy dry-type transformers combine a low-loss amorphous metal core with resin-insulated windings for indoor power distribution. The series is designed for projects where continuous operation, low no-load loss, fire-sensitive installation and reduced lifecycle energy consumption are important.

Standard 6kV and 10kV configurations are available from 30kVA to 2500kVA. Voltage ratio, capacity, vector group, enclosure, cooling and monitoring accessories can be customized after technical review.


Primary Voltage35, 34.5, 24, 20, 15, 13.8, 13.2, 11, 10.5, 10, 6.3, 6 kV or others
Secondary Voltage600 V, 480 V, 415 V, 400 V, 380 V or others
Vector GroupDyn11, Dyn5, Yyn0 or others
Impedance4%, 6%
Capacity (Power Rating)30 kVA, 45 kVA, 75kVA, 112.5kVA, 150kVA, 225kVA, 300kVA, 500kVA, 1000kVA, 1500 kVA, 2000 kVA, 2500kVA, 3000kVA
H.V. Tap Range±2 × 2.5% or others
BIL (Basic Insulation Level)30–150 kV
StandardsIEC, IEEE, ANSI, DOE
CertificatesCE, SGS, CNAS


Lower No-Load Loss for Continuous Operation

A Silent Dry Type Amorphous Core Transformer continues to generate core loss whenever it is energized, even when the connected load is low. The amorphous alloy core has lower hysteresis and eddy-current loss than a conventional silicon-steel core, helping reduce continuous no-load energy consumption.

This makes the SCBH15 amorphous alloy dry-type transformer suitable for facilities that operate 24 hours a day or spend long periods under light and medium loads.

Exact energy savings must be calculated using transformers of the same capacity, voltage ratio, load profile and test standard.


Features of Silent Dry Type Amorphous Core Transformer

1. Low partial discharge and long service life.

2. No oil, no pollution, flame-retardant and self-extinguishing.

3. Easy installation, no debugging needed, maintenance-free, low operating cost.

4. Equipped with a complete temperature protection and control system for safe operation.

5. Coils are resin-cast for high mechanical strength, improving short-circuit withstand capability.

6. Excellent moisture and corrosion resistance—ideal for harsh environments. After shutdown, it can be put back into service without drying.

7. High energy efficiency: It reduces no-load loss by about 60% and no-load current by about 60% compared with SCB10 transformers of the same capacity.

Why Choose an SCBH15 Amorphous Alloy Dry Type Transformer?

Amorphous Alloy Core

Thin amorphous alloy strips reduce magnetic core loss. The core support structure is designed to control vibration and maintain mechanical stability.

Resin-Insulated Windings

The windings use copper wire or foil with insulation and mechanical reinforcement. Resin processing helps provide dielectric strength, moisture resistance and short-circuit withstand capability.

AN or AF Cooling

Natural air cooling is available for standard operation. Forced-air cooling can be specified when additional thermal capacity is required. Any temporary capacity increase under AF cooling must be confirmed in the approved rating data.

Oil-Free Indoor Installation

The dry-type structure contains no transformer oil, making it suitable for indoor locations where fire safety, cleanliness and reduced oil-related maintenance are important.


Applications of Silent Dry Type Amorphous Core Transformer


This amorphous alloy dry-type transformer is widely used in projects that require both safety and energy efficiency:

  • ·   Industrial manufacturing plants

  • ·   Commercial buildings and office complexes

  • ·   Data centers and IT infrastructure

  • ·   Hospitals and public facilities

  • ·   Urban power distribution systems

  • ·   Energy-saving retrofit projects

  • ·   Indoor substations and distribution rooms


Amorphous Alloy Dry Type vs. Conventional Dry Type Transformer


The main difference is the magnetic core. An amorphous alloy core uses thin metal ribbon with a non-crystalline structure; a conventional core uses laminated crystalline silicon steel. The amorphous material's magnetic properties and thin ribbon construction help reduce hysteresis and eddy-current losses.


This primarily benefits no-load loss, which continues while the transformer is energized. Load loss also depends on winding design, current and temperature, so both loss components should be compared when selecting a transformer.


Selection factorSCBH15 Amorphous Alloy Dry Type TypeConventional silicon-steel dry type
Core materialAmorphous alloy ribbonLaminated silicon steel
No-load lossDesigned to reduce continuous core losses; verify the model valueUse the proposed model's tested or guaranteed value as the comparison baseline
Long energization hoursA lower no-load loss can accumulate meaningful annual savingsAssess the same operating hours and load profile
High-load operationCompare load loss and thermal performance as well as core lossThe complete loss profile remains important
Noise and footprintConfirm the offered model's sound data and drawingCompare under the same acoustic and installation conditions
Purchase decisionEvaluate additional installed cost against operating savingsEvaluate the complete quoted design and lifecycle cost

Both designs can serve indoor, oil-free distribution. Compare units with the same capacity, voltage ratio, frequency and relevant test conditions. Our Cast Resin Dry Type Transformer range provides another product route for project comparison.


Production of Silent Dry Type Amorphous Core Transformer

01 Production Equipments for dry type transformers

Amorphous Alloy Dry Type Transformer

02 Details of Dry type transformer

Amorphous Alloy Dry Type Transformer

03 Production workshop of Dry Type Transformers

Amorphous Alloy Dry Type Transformer

04 Routine Test of Dry Type Transformers

Amorphous Alloy Dry Type Transformer

Package and Shipping

Amorphous Alloy Dry Type Transformer


Customization Options for Your Project


TAILI can review the following requirements for the selected SCBH15 design. The technical offer should identify the accepted configuration and corresponding performance values.

Customization itemInformation to provide
Voltage ratioRated HV/LV, system voltage and HV tap range
CapacityRated kVA, expected demand, load profile and planned expansion
Vector groupRequired connection group, grounding arrangement and any parallel-operation requirement
ImpedanceTarget value and project acceptance tolerance
EnclosureRequired protection, material, cable entry and available space
Cooling methodAN or AF, expected ambient conditions and any required fan-assisted rating
Temperature monitoringSensors, controller, alarm, trip, fan control and remote-signal requirements for review
Installation environmentIndoor or protected installation, altitude, temperature, humidity, dust, corrosion exposure, ventilation and acoustic limits
Frequency50 Hz or 60 Hz and the applicable project specification

Service System

Quality Control: Our quality control system is comprehensive and multi-faceted. From the initial selection of high-grade raw materials sourced from reliable suppliers, we ensure that every component used in our Amorphous Metal Transformers meets the highest quality standards.


Routine Tests:

Measurement of winding resistance

Measurement of voltage ratio

Check of vector group

Mesurement of impendance voltage and load loss

Measurement of no load oss and current

Separate-source voltage withstand test

Induced overvoltage withstand test

Dimension checking


Type Tests

Lighting impulse test

Temperature rise test


Flexible Customization for Global Projects

We provide customized solutions to meet different project and regional requirements:

  • ·   Voltage levels and frequency (50Hz / 60Hz)

  • ·   Capacity and impedance design

  • ·   Cooling methods and enclosure options

  • ·   Installation type and protection level

  • ·   Compliance with international standards

This flexibility allows the Amorphous Metal Transformer to adapt to various industrial, commercial, and infrastructure applications.


Why Source SCBH15 Transformers from TAILI?


◆  Electrical equipment manufacturing experience: TAILI's history dates to 1988, with a product portfolio that includes transformers, switchgear and substations.

◆  Project configuration support: Our engineering team reviews electrical and installation requirements to support the proposed distribution arrangement.

◆  Factory verification: TAILI lists checks for ratio, vector group, winding resistance, losses, no-load current, impedance and dielectric performance. Specify required routine reports and applicable type-test evidence in the purchase documents.

For a wider overview of our distribution products, explore the Dry Type Transformer range.


FAQ


What is an amorphous core transformer?
An amorphous core transformer uses amorphous metal materials in the core to reduce magnetic loss and improve energy efficiency.

What is the advantage over silicon steel transformers?
The main advantage is significantly lower no-load loss, which reduces energy consumption during operation.

Where is it typically used?
It is widely used in industrial plants, commercial buildings, data centers, and indoor substations.

Is it suitable for indoor installation?
Yes, as a dry-type transformer, it is designed for safe indoor use without oil-related risks.

Can it be customized?
Yes, voltage, capacity, cooling method, and enclosure can be customized based on project requirements.

Can TAILI provide guaranteed loss values?

Yes. Model-specific no-load loss, load loss, impedance and no-load current can be confirmed in the technical agreement and verified during factory testing.


Leave your Message

    * Upload the technical sheet of the transformer