3-Phase Oil Immersed Distribution Transformers

2000 kVA transformer
33/0.4 kV Oil-Immersed Transformer
ONAN distribution transformer
2000 kVA transformer
33/0.4 kV Oil-Immersed Transformer
ONAN distribution transformer

2000 kVA 33/0.4 kV Oil-Immersed Transformer with Conservator Tank

The 2000 kVA 33/0.4 kV oil-immersed transformer with conservator tank is designed for medium-voltage power distribution systems, converting 33 kV primary voltage to 0.4 kV secondary voltage. Operating at 50 Hz, this three-phase distribution transformer features copper windings, a Dyn11 vector group, and an impedance voltage of 5.8%.

Equipped with an ONAN cooling system and a conservator tank, the transformer uses natural oil circulation and natural air cooling for heat dissipation. Its voltage adjustment range of ±2 × 2.5% provides flexibility for adjusting the voltage ratio to suit different supply voltage conditions. The transformer is designed in accordance with the applicable requirements of the IEC 60076 series of standards.


Share:

Performance parameters for reference

ParameterSpecification
Product TypeOil-Immersed Distribution Transformer
Rated Capacity2000 kVA
Rated Voltage33/0.4 kV
Frequency50 Hz
PhasesThree-Phase
Vector GroupDyn11
Impedance Voltage5.8%
Cooling MethodONAN
Winding MaterialCopper
Oil PreservationConservator Tank
Voltage Adjustment Range±2 × 2.5%
Applicable StandardIEC 60076

Additional parameters, including no-load loss, load loss, insulation levels, temperature rise, tap changer configuration, and protective accessories, can be specified according to project requirements.


Key Features

Conservator Tank Design

The conservator tank accommodates changes in insulating oil volume caused by temperature variations during operation. It helps maintain an appropriate oil level in the main tank as the oil expands and contracts, supporting the transformer's insulation and cooling functions.

Copper Windings

Copper windings provide good electrical conductivity and can be designed to meet the transformer's electrical and mechanical requirements. The winding design considers rated capacity, voltage requirements, temperature-rise limits, and specified operating conditions.

ONAN Cooling System

The ONAN (Oil Natural Air Natural) cooling system relies on natural oil circulation inside the transformer and natural air circulation around its external cooling surfaces. It does not require oil pumps or cooling fans for normal cooling operation, providing a relatively simple cooling arrangement.

Adjustable Voltage Ratio

The transformer features a voltage adjustment range of ±2 × 2.5%, allowing the voltage ratio to be adjusted to accommodate variations in the incoming medium-voltage supply. The tap changer type, available tap positions, and adjustment procedure depend on the specified configuration. If an off-circuit tap changer is used, the transformer must be de-energized before changing tap positions.

Dyn11 Vector Group

The Dyn11 connection features a delta-connected high-voltage winding and a star-connected low-voltage winding with a neutral terminal. This configuration is commonly used in three-phase, four-wire distribution systems, subject to the network grounding arrangement and project requirements.

IEC 60076 Design Requirements

The transformer is designed in accordance with the applicable requirements of the IEC 60076 series of standards for power transformers. Specific design, performance, and testing requirements are determined by the applicable standard provisions and the agreed technical specification.


Contact us
Typical Applications

The 2000 kVA 33/0.4 kV oil-immersed transformer is suitable for various medium-voltage power distribution applications, including:

Industrial plants and manufacturing facilities

Commercial buildings and business complexes

Medium-voltage distribution substations

Infrastructure and utility distribution projects

Agricultural and other three-phase power distribution systems

Final selection should take into account the actual load profile, incoming grid voltage, installation environment, protection arrangements, and local electrical requirements.


Routine Tests Before Delivery

The transformer undergoes applicable routine tests before delivery in accordance with the agreed technical specification and relevant requirements of IEC 60076. These tests help verify key electrical characteristics and insulation performance before shipment.

Typical routine tests include:

Winding Resistance Measurement: Measures winding resistance to help verify electrical continuity and identify potential winding discrepancies.

Voltage Ratio Measurement: Verifies the voltage ratio at the specified tap positions.

Vector Group and Phase Displacement Verification: Confirms the specified Dyn11 connection and phase displacement.

No-Load Loss and No-Load Current Measurement: Evaluates the transformer's excitation characteristics under no-load conditions.

Load Loss and Short-Circuit Impedance Measurement: Measures load-related losses and verifies the impedance characteristics.

Applied Voltage Withstand Test: Checks the insulation between the designated winding and earth or other specified circuits.

Induced Voltage Withstand Test: Evaluates the insulation between turns and between winding sections, as applicable to the test arrangement.

Test results are documented in the factory test report according to the agreed inspection and documentation requirements. Additional tests or inspections can be arranged when specified in the contract.


Customized Transformer Solutions

TAL Transformer provides oil-immersed transformer solutions for different voltage levels, rated capacities, and project specifications. Configurations can be discussed according to customer requirements, including winding materials, voltage adjustment arrangements, oil preservation systems, tank design, and protection accessories.

This 2000 kVA 33/0.4 kV oil-immersed transformer combines a conservator tank, copper windings, ONAN cooling, and a Dyn11 connection for medium-voltage power distribution applications. Its final technical configuration, testing requirements, and delivery documentation can be confirmed against the customer's project specification before production.