3-Phase Oil Immersed Distribution Transformers

1250kVA oil immersed transformer,
33/0.4kV transformer
OLTC transformer
1250kVA oil immersed transformer,
33/0.4kV transformer
OLTC transformer

11/0.41kV-630kVA Distribution Transformer with DGPT2

Custom-built for African tropical climate and unstable power grid, this 630kVA transformer adopts 100% pure copper winding. It comes standard with DGPT2 protection relay compatible with AUTOMATION 2000 system for comprehensive fault monitoring and trip protection.


Two high-voltage connection options are available: plug-in bushing for compact installation and porcelain insulator for open-air outdoor sites. Excellent resistance against high temperature, humidity, dust and salt-spray, widely used for grid renovation, rural electrification, mining, solar-power supporting and industrial power supply projects .

 


Share:

Basic Info.

Our H61 series 630KVA 11/0.41KV distribution transformer is specially optimized and customized for complex African power grid conditions and harsh tropical outdoor environments. Adopting full copper winding and standard Dyn11 vector group design, this transformer delivers stable voltage output, strong overload resistance and outstanding harmonic suppression capability, perfectly adapting to local voltage fluctuation, high temperature, high humidity and heavy load operation scenarios. Equipped with professional DGPT2 intelligent protection relay, it realizes full-condition operational safety protection. Meanwhile, we provide two flexible high-voltage connection solutions (plug-in bushing & porcelain insulator) to meet diverse installation and construction demands of African urban power grids, rural power renovation and industrial power supply projects.


Application Scenarios


Widely applicable for national grid renovation, rural electrification projects, industrial and mining enterprises, commercial buildings, solar/wind power supporting power distribution, outdoor box substations and public power supply projects in Nigeria, Ghana, Kenya, Tanzania, South Africa, Congo and other African countries and regions.


Technical Specifications

Rated Capacity630KVA
Rated Voltage11 / 0.41KV
Vector GroupDyn11
Winding MaterialCopper or Aluminum (optional)
Cooling MethodONAN
Operation Frequency 50Hz



Contact us
Standard Configuration: DGPT2 Intelligent Protection Relay (AUTOMATION 2000)

All units are pre-installed with DGPT2 professional transformer comprehensive protection relay supporting AUTOMATION 2000 system, a core safety configuration tailored for unstable African power grids. It achieves real-time monitoring and automatic protection against overvoltage, undervoltage, overload, short circuit, over temperature and gas faults. The intelligent early warning and trip protection functions effectively avoid transformer burnout caused by local grid voltage fluctuation and frequent load impact, ensuring long-term safe and stable operation of equipment and reducing post-operation failure and maintenance costs.


Two Custom High-Voltage Connection Solutions

01 Plug-in (Plug-in Bushing) Solution

Featuring fast plug-and-play installation, compact structure and excellent waterproof and dustproof performance. It is suitable for urban compact power distribution stations, box-type substations and limited-space installation scenarios. The fully sealed design effectively resists tropical rain, dust and coastal salt spray corrosion, reducing on-site wiring workload and greatly shortening construction cycle.

02 Porcelain Insulator Solution

Adopting high-strength anti-fouling porcelain bushing, with superior high voltage resistance, creepage resistance and mechanical stability. It is ideal for open-air outdoor substations, rural overhead power supply lines and remote industrial power supply projects in Africa. It adapts to harsh weather such as strong wind, thunderstorm and high temperature, with low maintenance cost and ultra-long service life.

Contact Us

Key Advantages for African Market

Full Copper Winding & Low Loss: 

Pure copper windings ensure lower resistance, lower no-load/load loss, better heat dissipation and higher power transmission efficiency than aluminum winding transformers. It stably copes with long-term high-load operation in African industrial and mining, residential power supply scenarios.

Dyn11 Vector Group Grid Adaptability: 

Effectively suppresses grid harmonics, balances three-phase current, reduces zero-sequence current impact, and perfectly adapts to unstable local power quality and frequent load changes in Africa.

Harsh Environment Resistance: 

Optimized for African tropical climates (high temperature, high humidity, heavy rain, dust and salt spray). The whole machine adopts anti-corrosion paint and sealed structure, with strong weather resistance and wide temperature operation range.

Intelligent Safety Protection: 

Built-in DGPT2 relay realizes full-dimensional fault monitoring and automatic protection, solving the pain point of high transformer failure rate caused by poor local grid stability.

Dual Installation Compatibility: 

Dual high-voltage connection schemes cover all mainstream African power distribution installation modes, applicable to new energy power stations, urban and rural grid renovation, factory power supply, mining power distribution and other scenarios.

Stable & Durable: 

Strictly manufactured in accordance with international standards, with rigorous factory testing, low failure rate and minimal daily maintenance, saving long-term operating costs for African customers.


FAQ

1. Why choose full copper winding transformers for African power projects?

Full copper windings deliver lower power loss, superior heat dissipation, higher overload tolerance and longer service life than aluminum alternatives. They perform stably under Africa’s unstable grids and frequent heavy loads, cutting long-term energy and maintenance costs for power projects.


2. What is the difference between plug-in and porcelain insulator HV solutions?

The plug-in bushing features fast plug-and-play installation, full waterproof and dustproof sealing, perfect for compact urban substations and space-limited sites. The porcelain insulator boasts high mechanical strength, anti-pollution and lightning resistance, ideal for open-air rural overhead lines and remote outdoor power stations.


3. What functions does the DGPT2 (AUTOMATION 2000) relay support?

The built-in DGPT2 relay compatible with AUTOMATION 2000 system provides 24/7 real-time monitoring and automatic trip protection against overvoltage, undervoltage, overload, short circuit, overheating and gas faults. It effectively prevents transformer damage from African grid voltage fluctuations and unstable loads.


4. Is this transformer suitable for African tropical harsh environments?

Yes. This H61 series is tailor-made for African tropical climates. Equipped with anti-corrosion coating, fully sealed structure and high-grade insulation, it resists high temperature, high humidity, rain, dust and salt spray for stable long-term outdoor operation.


5. Do you support customized parameters and bulk export for African projects?

Yes. We support full customization of capacity, voltage ratio and accessories. With rich African export experience, we provide one-stop solutions including standard export packaging, ocean shipping arrangement and professional on-site technical guidance for bulk orders.


Leave your Message

    * Upload the technical sheet of the transformer